Silver and nickel/silver knits, wovens, non-wovens and hook & loop. Shielding effectiveness from −40 dB to −70 dB at 1 GHz, weights from 0.7 oz/yd², widths to 76". Filter below, compare what fits, and request a sample.
Know the part number? K087S · K158S · K252S · W077S · W077NS · W823NS · NPB20NS · SMS-0102/0103
Four families, one bonding process underneath. Start where the requirement points.
The elastomer systems the fabric is built into — the deliverables of the survivability stack. No published data sheet yet; the family page carries them.
Elastomers · tech sheets →Conductivity at the lowest weight in the line, in widths to 76". Where every ounce is negotiated. Spandex (K252S) lives here.
Filter to knits → Tech sheets →Rip stop and taffeta in silver or nickel/silver — including the lowest surface resistance in the line at 0.06 Ω/sq. Hook & loop lives here.
Filter to wovens → Tech sheets →The most shielding in the line, and breathable with it — 814 g/m²/24 h water-vapor transmission. Also supplied as fiber mats and veils.
Filter to non-wovens → Tech sheets →→ Custom Engineered Material Solutions (Solutions)
STM modifies existing materials — coating, base fabric, weight, width — or develops new constructions from the application in. Since 1955.
Nine published materials. Every value below is a typical value from the current data sheet, measured to the ASTM method named on it.
URL carries filter state — sales can send a pre-filtered link; the same parameters pass through to Launchpad (§9).
| ☐ | Material | Family | Coating | SE @ 1 GHz | Thickness | Weight | Resistance | Width | Spec sheet |
|---|---|---|---|---|---|---|---|---|---|
| K087S | Knit | Ag | −42 dB | [ from sheet ] | 0.7 oz/yd² | 1.0 Ω/sq | to 76" | PDF SMS-0105 | |
| K158S | Knit | Ag | −55 dB | [ from sheet ] | 1.5 oz/yd² | 0.3 Ω/sq | 48" | PDF SMS-0106 | |
| W077S | Woven | Ag | −65 dB | [ from sheet ] | 1.4 oz/yd² | 0.3 Ω/sq | 36–37" | PDF SMS-0116 | |
| W077NS | Woven | Ni/Ag | −65 dB | [ from sheet ] | 1.7 oz/yd² | 0.06 Ω/sq | 36–37" | PDF SMS-0115 | |
| W823NS | Woven | Ni/Ag | −65 dB | [ from sheet ] | 2.4 oz/yd² | 0.1 Ω/sq | 36–37" | PDF SMS-0118 | |
| NPB20NS | Non-woven | Ni/Ag | −70 dB | [ from sheet ] | 3.0 oz/yd² | 0.1 Ω/sq | 36–37" | PDF SMS-0113 | |
| K252S | Knit (spandex) | Ag, high-purity | −40 dB | [ from sheet ] | 4.7 oz/yd² | <1.5 Ω/sq | 72" | PDF SMS-0155 | |
| Hook, Ag | Woven (hook & loop) | Ag | n/a † | [ from sheet ] | 11.0 oz/yd² | 0.02 Ω·cm (paired) | 1", 2" × 50 yd | PDF SMS-0102 | |
| Loop, Ag | Woven (hook & loop) | Ag | n/a † | [ from sheet ] | 11.0 oz/yd² | 0.02 Ω·cm (paired) | 1", 2" × 50 yd | PDF SMS-0103 |
† Hook and loop are specified by volume resistivity across the paired closure, not by shielding effectiveness.
All values are typical, drawn from multiple production batches. The data sheet governs.
Every fabric sheet carries an independent free-space shielding-effectiveness curve measured by a third-party lab from 2 to 40 GHz.
No standard material meets all of that at once — which usually means you're describing a custom construction. That's a normal place to be here.
| Property | K087S | W077NS | NPB20NS |
|---|---|---|---|
| Shielding effectiveness @ 1 GHz | −42 dB | −65 dB | −70 dB |
| Shielding curve 2–40 GHz | [ static curve image ] | [ static curve image ] | [ static curve image ] |
| Thickness | [ from sheet ] | [ from sheet ] | [ from sheet ] |
| Weight | 0.7 oz/yd² | 1.7 oz/yd² | 3.0 oz/yd² |
| Electrical resistance | 1.0 Ω/sq | 0.06 Ω/sq | 0.1 Ω/sq |
| Tensile strength MD/CMD | [ from sheet ] | 12,000 / 10,000 psi | [ from sheet ] |
| Elongation MD/CMD | 75 / 80% | [ from sheet ] | [ from sheet ] |
| Tear strength | [ from sheet ] | [ from sheet ] | [ from sheet ] |
| Water-vapor transmission | n/a — not specified for this construction | n/a — not specified for this construction | 814 g/m²/24 h |
| Base fabric | Knit scrim 48×21 | Rip stop | Point-bonded non-woven |
| Base fiber | [ from sheet ] | [ from sheet ] | [ from sheet ] |
| Coating | Ag | Ni/Ag | Ni/Ag |
| Width | to 76" | 36–37" | 36–37" |
| Test methods | ASTM D4935 · D4496 · D3776 | ASTM D4935 · D4496 · D3776 | ASTM D4935 · D4496 · D3776 |
STM has been engineering custom conductive fabrics since 1955. Most requirements are met by modifying an existing material — coating, base fabric, weight or width. Some become an entirely new construction, co-developed from the application in. Either way it starts with a conversation, not a part number.
Just because it isn't on the list today doesn't mean it can't be built. That's most of what we do.
The EnCap™ process chemically bonds metal to the fiber at the molecular level, encapsulating each fiber 100% — every filament, all the way around, with no shadow side. The base fabric keeps its stretch, drape, tear strength and breathability, and the conductivity becomes a property of the material rather than a layer on top of it. That's why these values survive flex, abrasion and environmental exposure instead of degrading with cycles.
How EnCap™ works →Aerospace & Defense — Composite integration, conductive ground plane, EMI gaskets, EMI/RF signal management and ESD protection, where every ounce is negotiated; shielded enclosures, cases, bags, pouches and pop-up shelters; signal isolation; and the conductive layer inside signature-management systems.
| Application | Knits | Wovens | Non-wovens | Hook & loop |
|---|---|---|---|---|
| Composite integration | ||||
| Conductive ground plane | ||||
| EMI gaskets | ||||
| EMI/RF signal management | ||||
| ESD protection |
Full Aerospace & Defense page →
Tab intro lines for the other three — Medical & Wearables: Pressure mapping, biosensors, wearables, defibrillation components and ESD, where consistency matters as much as conductivity. · Architectural & Secure Facilities: Faraday enclosures, SCIFs, labs, MRI suites, wall and window coverings — high attenuation without a vapor barrier. · Telecom & Industrial: Cable and harness wraps, RF blankets and barriers, cell-site and data-center shielding, dielectric test liners.
Every material's full published specification, plus current certifications. HTML spec pages are canonical and live under Resources (client sitemap, Sep 18); the PDF is the download.
⚑ The Sep 18 doc counts spec pages ×6; nine data sheets are published today. Reconcile the roster before the spec-page template is built.Launchpad is the fast lane when you know what you need: send your spec, drawing or RFQ — or the filters you just set — straight to sales for a quote. No screening call, no samples.
Prefer to talk it through? Talk to an Expert →
Whatever they select and enter should translate straight through the inquiry. The filter state is already in the URL for §3; the form reads the same parameters — so sales gets the spec up front, not a paragraph to decode.
⚑ Copy guardrail carried from the homepage: Launchpad shortens the discussion cycle, not the lead time — never word it as faster delivery.